Magni Systems, Inc. 64
9. APPLICATIONS
Typical Applications and their Respective Settings
There are many applications for the MCP-601 Series product. Scan Conversion, SDI video encoding,
Downstream keying and internal keying and overlay are the more common ones. Following are three typical
applications and the initial settings for each application:
APPLICATIONS
INITIAL
SETTINGS
PRESENTATION and
SCAN CONVERSION
INTERNAL KEY and
OVERLAY
EXTERNAL KEY and
OVERLAY
Config
-
Tab
g
-
Computer Input
Digital DVI (recommended) or analog VGA
Video Input
None (SCM*) SDI 601/ Analog None or SDI
Genlock Source
REF IN REF IN/ Input Video REF IN
Genlock BW
Broadcast Broadcast Broadcast
V Filter
Reduced Flicker Reduced Flicker Reduced Flicker
H Filter
H Filter ON H Filter ON H Filter ON
Mix
-
Tab
VGA Zoom 1 to 1
ON ON ON
Mix Level position
Graphics Graphics Graphics
Mix/Video Lights
Mix light ON
Mix light ON
Mix light ON
External KEY/MIX
Light OFF Light OFF Light ON
Key button
OFF ON ON
Size-Tab
Video Squeeze size
N/A (Any size) Any Size Full (Reset Video)
Key lockout
N/A (Reset Lockout) Full Size (Reset Full Size (Reset
Key
-
Tab
External Key
OFF OFF ON
Key Edge Filter
N/A Soft Soft
Key Width
N/A Wide Wide
Key Range
N/A 10 10
NOTE: * Scan Conversion Mode (SCM)
Table 9-1, Typical applications of the MCP-601 Scan Converter and the recommended
Magni Premier application software settings