MCP-601 Operator’s Manual
Magni Systems, Inc. 43
Factory Preset Default Memories (MCP-601)
Table 5-1a
Factory Preset Default Memories
1
VIDEO INPUT GRAPHICS Genlock VIDEO OUTPUT
KEY
8
MIX
FUNCTION Location
Setting
Resizer Input Resizer Source Format
Standard
6
Type Color Graphics/Video
Scan Conversion:
Scan Conversion, VGA/ No input
PowerUp
None
7
N/A VGA Full scan
Internal
Clock
SDI & CPST 525/ NTSC Off Black 100% / 0%
Scan Conversion, VGA/ Ref input
1 None N/A VGA
Underscan
2
REF-IN
4
SDI & CPST 525/ NTSC External Black 100% / 0%
Scan Conversion, DVI/SDI inputs
2 SDI N/A DVI
1:1 MagniPort
3
SDI SDI & CPST 525/ NTSC External Black 100% / 0%
Video Squeeze:
Split-screen 56% size Video
3 CPST
56%
(3/4x3/4)
VGA Underscan
Video In
5
SDI & CPST 525/ NTSC Off Black 0% / 100%
Split-screen 25% size Video
4 CPST
25%
(1/2x1/2)
VGA Underscan Video In SDI & CPST 525/ NTSC Off Black 0% / 100%
Overlay, Keying and Mixing:
VGA Zoom 1 to 1, Standard Key
5 CPST 100% VGA
1:1 MagniPort
3
Video In
5
SDI & CPST 525/ NTSC Standard Black 100% / 0%
Transparent Key Mode
6 CPST 100% VGA Underscan Video In SDI & CPST 525/ NTSC Transparent
BLK/WHT
9
100% / 0%
Graphics Key Mode
7 CPST 100% VGA Underscan Video In SDI & CPST 525/ NTSC Graphics White 100% / 0%
Video (Chroma) Key Mode
8 CPST 100% VGA Underscan Video In SDI & CPST 525/ NTSC Video Blue 100% / 0%
Mix, Analog Video (CPST)/ VGA
9 CPST 100% VGA Underscan Video In SDI & CPST 525/ NTSC Off Black 50% / 50%
Mix, DVI/ SDI inputs
10 SDI 100% DVI 1:1 MagniPort SDI SDI & CPST 525/ NTSC Off Black 50% / 50%
NOTES:
(1) Factory preset default memories are hard coded. However, user can modify all 11 memories setting to suit their applications. The modified memories are save separately in
non-volatile locations.
(2) Underscan mode: The full graphics screen will be resized to fit in 92%, in both horizontal and vertical directions, of the output video screen.
(3) MagniPort with a window size of 720x480 within the graphics screen to be converted to a full or underscan NTSC/ 525 video output.
(720x576 for PAL /625 Standard)
(4) REF-IN input can be either a Color Black (Black Burst) or a Composite signal.
(5) Outputs automatically genlock to the selected video input. Except in the case of SDI input, the subcarrier phase of analog Composite output can be set to lock to the chroma
phase of REF-IN video input.
(6) Factory default standard with no video input is set to 525 (NTSC). It can change to 625 (PAL) during initial setup. It can also be set from MENU to “Default to NTSC or
Default to PAL”. The standard always follows the genlock source, and auto switch between 625/PAL and 525/NTSC.
(7) With no input signal, will reference to default standard.
(8) Filters and Key settings: Input Filter: Reduced Flicker, H Filter: On, Key Edge Filter: Soft, Key Width: Wide, Key Range: 25.
(9) BLK (black) key color for Standard Key and WHT (white) represents transparent key color.